Western blot protocol

Procedure for western blotting

Solutions and reagents:

Lysis buffers

These buffers may be stored at 4°C for several weeks or for up to a year aliquoted and stored at -20°C.

RIPA buffer (Sigma #R0278)
Complete Protease Inhibitor cocktail (Roche #)

PhosSTOP Phosphatase inhibitor Cocktail (Roche #)


1xTBS buffer
20 mM Tris-HCl

150 mM NaCl

Milli-Q Water

pH 7.5

1xTBST buffer

1xTBS buffer

0.1% (v/v) Tween-20

pH 7.5


Running Buffer

100 ml 10x Tris/Glycine/SDS (Bio-Rad #161-0732)

900 ml Milli-Q water


Transfer Buffer

100 ml 10x Tris/Glycine (Bio-Rad #161-0734)

200 ml methanol

700 ml Milli-Q water


Blocking buffer

5% (w/v) milk

Add to TBS buffer. Mix well.


Antibody dilution buffer
5% (w/v) milk

Add to TBST buffer. Mix well.


Procedure:

1. Sample lysis

Preparation of lysate from cell culture

1.     Place the cell culture dish in ice and wash the cells with ice-cold PBS.

2.     Aspirate the PBS, then add ice-cold lysis buffer (1 ml per 107 cells/100 mm dish/150 cm2   flask; 0.5ml per 5x106 cells / 60 mm dish / 75 cm2 flask).

3.     Scrape adherent cells off the dish using a cold plastic cell scraper, then gently transfer the cell suspension into a pre-cooled microcentrifuge tube.

4.     Maintain constant agitation for 30 minutes at 4°C.

5.     Sonicate for 1 minutes (2 seconds working and 3 seconds rest for each cycle)

6.     Spin at 16,000 x g for 20 minutes in a 4°C pre-cooled centrifuge.

7.     Gently remove the tube from the centrifuge and place on ice. Transfer the supernatant to a fresh tube kept on ice, and discard the pellet.

2. Sample preparation

1.     Determine the protein concentration for each cell lysate. (Appendix 1)

2.     To the remaining volume of cell lysate, adjust the concentration of cell lysate at 1 ug/ul with lysis buffer, 4xSample Buffer (Invitrogen # NP0007) and 10xSample Reducing Agent (Invitrogen # NP0009).

3.     To reduce and denature: Boil each cell lysate in sample buffer at 100°C for 5 minutes and aliquot. Store lysates at -20°C. Note: aliquot cell lysates (50- 100 μl) to avoid repeat freeze/thaw cycles.

4.     Defrost tubes containing cell lysate at 37°C. Centrifuge at 16,000 x g in a microcentrifuge for 5 minutes.

3. Loading and running the gel

1.     Load equal amounts of protein into the wells of the SDS-PAGE gel (Bio-Rad # 567-1085), along with molecular weight markers. Load 10- 40 μg of total protein from cell lysate.

2.     Run the gel for 1 to 2 hours at 100 V.

4. Transferring the protein from the gel to the membrane

  1. Cut off nick top left-hand corner of resolving gel for orientation.
  2. Measure the dimensions of the gel and note the positions of the ladder bands.
  3. Transfer gel, while still attached to glass plate, to box containing TGM and peel off gently with a spatula.
  4.  Agitate 15-20 seconds at RT to remove salts and SDS.
  5. Cut a piece of PVDF membrane to the size of the gel and mark and/or clip one corner as the top left-hand corner. Handle only with flat forceps.
  6. Immerse membrane in Transfer buffer for 10-15 seconds.
  7. Cut 2 pieces of >3mm filter paper to the dimensions of the gel (or slightly bigger).
  8. Open a gel holder cassette in a casserole dish, black side down and hinges to the left and below the black side.
  9. Soak a fiber pad with Transfer buffer and place in the center of the black side.
  10. Soak one piece of filter paper with Transfer buffer and place on top of the fiber pad.
  11. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  12. Place gel on top of filter paper.
  13. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  14. Place membrane on top of gel, with the gel’s top left mark facing the membrane’s top left mark.
  15. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  16. Soak a second piece of filter paper with Transfer buffer and place on top of the membrane.
  17. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  18. Soak a second piece of fiber pad and place on top of stack.
  19. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  20. Close the gel holder cassette.
  21. Place in a transfer tank (orient the red and black sides of the cassette with the red and black panels of the electrode) and fill with Transfer buffer (~2000ml).
  22. Place the tank in a styrofoam box containing ice.
  23. Run 75 minutes at 100V.

5. Antibody staining

1.     Block the membrane for 1-2 hours at room temperature using 5% blocking solution.

2.     Incubate membrane with appropriate dilutions of primary antibody (Appendix 2) in antibody dilution buffer overnight at 4°C.

3.     Wash the membrane in three washes of 1xTBST, 5 minutes each.

4.     Incubate the membrane with the recommended dilution of labeled secondary antibody in antibody dilution buffer at room temperature for 1 hour.

5.     Wash the membrane in three washes of 1xTBST, 5 minutes each, then rinse in 1xTBS.

6.     Scan the membrane according to the manual of Obyssey.




Appendix 1

Preparation of Standards and Working Reagent

A. Preparation of Diluted Albumin (BSA) Standards

Use Table 1 as a guide to prepare a set of protein standards. Dilute the contents of one Albumin Standard (BSA) ampule into several clean vials, preferably using the same diluent as the sample(s). Each 1mL ampule of 2mg/mL Albumin Standard is sufficient to prepare a set of diluted standards for either working range suggested in Table 1. There will be sufficient volume for three replications of each diluted standard. Table 1. Preparation of Diluted Albumin (BSA) Standards

Dilution Scheme for Standard Test Tube Protocol and Microplate Procedure (Working Range = 20-2,000μg/mL)

Vial

Volume of Diluent

(μL)

Volume and Source of BSA (μL)

Final BSA Concentration (μg/mL)

A

0

300 of Stock

2000

B

125

375 of Stock

1500

C

325

325 of Stock

1000

D

175

175 of vial B dilution

750

E

325

325 of vial C dilution

500

F

325

325 of vial E dilution

250

G

325

325 of vial F dilution

125

H

400

100 of vial G dilution

25

I

400

0

0 = Blank

B. Preparation of the BCA Working Reagent (WR)

1. Use the following formula to determine the total volume of WR required:

(# standards + # unknowns) × (# replicates) × (volume of WR per sample) = total volume WR required

Example: for the standard test-tube procedure with 3 unknowns and 2 replicates of each sample:

(9 standards + 3 unknowns) × (2 replicates) × (2mL) = 48mL WR required

Note: 2.0mL of the WR is required for each sample in the test-tube procedure, while only 200 μl of WR reagent is required for each sample in the microplate procedure.

2. Prepare WR by mixing 50 parts of BCA Reagent A with 1 part of BCA Reagent B (50:1, Reagent A:B). For the above example, combine 50mL of Reagent A with 1mL of Reagent B.

Note: When Reagent B is first added to Reagent A, turbidity is observed that quickly disappears upon mixing to yield a clear, green WR. Prepare sufficient volume of WR based on the number of samples to be assayed. The WR is stable for several days when stored in a closed container at room temperature (RT).

Microplate Procedure (Sample to WR ratio = 1:8)

1. Pipette 25μL of each standard or unknown sample replicate into a microplate well (working range = 20-2000μg/mL).

Note: If sample size is limited, 10μL of each unknown sample and standard can be used (sample to WR ratio = 1:20). However, the working range of the assay in this case will be limited to 125-2000μg/mL.

2. Add 200μL of the WR to each well and mix plate thoroughly on a plate shaker for 30 seconds.

3. Cover plate and incubate at 37°C for 30 minutes.

4. Cool plate to RT. Measure the absorbance at or near 562nm on a plate reader.


 

 

化工儀器網

推薦收藏該企業網站
主站蜘蛛池模板: 中文字幕一区二区在线观看 | 欧美福利 | 色综合天天综一个色天天综合网 | 欧美1区2区| 小视频在线看 | 日韩视频高清 | 久久精品中文字幕 | 国产精品冒白浆免费视频 | 午夜小视频在线播放 | 久久久久女人精品毛片 | 成人欧美一区二区三区在线观看 | 久久综合桃花 | 亚洲欧美在线观看视频 | 久久综合丝袜日本网 | 久久好在线视频 | 免费啪视频在线观看免费的 | 99久久99久久 | 特黄免费 | 亚洲天堂免费在线 | 天天拍天天干天天操 | www.久久久 | 免费看片网址 | 日本午夜大片免费观看视频 | 欧美在线观看视频一区 | 毛片在线观看视频 | 精品的一区二区三区 | 久久久国 | 亚洲国产一区二区视频 | 亚洲综合色婷婷 | 久久精品中文字幕首页 | 午夜影视在线观看免费完整高清大全 | 国产中文字幕在线 | 美女被免费网站在线视频九色 | 黄色片免费在线 | 欧美成人h版在线观看 | 日日爱视频 | 国内精品伊人久久 | 亚洲国产精品久久 | 春色av | 国产99精品| 小视频你懂得 |